1 RONGD 2366-994-1-31 FLOATER
E TYPE LEVEL SENSOR
ENGINE FLOATER TYPE LEVEL
ERING: SENSOR
2366- SPECIFICATION
994-1-31 1.TYPE:RDHL-B2
2.SIGNAL:NORMAL.
3K?/ALARM-1.5K?(BEED SWITCH IS NC TYPE)
3.PROTECTION:IP68
4.EX-PROOF:EXIAIICT6
5.TRANSMITTER MATERIAL:SUS304
2 RONGD 2366-994-1-30 PRESSURE
E TYPE LEVEL SENSOR
ENGINE PRESSURE TYPE LEVEL
ERING: SENSOR
2366- SPECIFICATION
994-1-30 TYPE:RDLY-S
PROTECTION:IP68
EX-PROOF:EXIA II CT6 OUTPUT SIGNAL:4-20MA MATERIAL: SUS304
3 RONGD RDAO-1ZENER
E BARRIER
ENGINE ZENER BARRIER
ERING: TYPE:RDAQ-1
RDAQ-
1 、Pressure type level sensor,Spec.Type: RDLY-S. DC24V,2Wires,
Ambient Temp-(-10 to 55 deg), Output 4 to 20mA
ProtectionIP68Range 0 to50kPa.
Cable length 2mtr 2701-215-01-10 Pos.9-12 4
2、 Pressure type level sensor,Spec.Type:RDLY-S. DC24V,2Wires,
Ambient Temp-(-10 to 55 deg), Output 4 to 20mA
Protection IP68Range 0 to 60kPa,
Cable length 2mtr 2701-215-01-10 Pos. 23 1
3、 Pressure type level sensorSpec.Type:RDLY-S. DC24V, 2Wires,
Ambient Temp-(-10 to 55 deg), Output 4 to 20mA
Protection IP68Range 0 to 70kPa.
Cable length 2mtr 2701-215-01-10 Pos.6 1
4、 Temperature sensor,Type: WZPK-P223A
,RangeO to 100deg. PT100.ExProof: Exia II CT6.
Protection:IP56.Material 304
External 3 core cable 2701-215-01-17 — 8
“Pressure transmitter for F.P.T.
Type: RDLY-S
Power: 24DC
Output: 4-20 mA
Protection: IP68
Range: 0-240 kPa
Cable: 30 m”
“Level switch for Pipe Tunnel
Type: RDHL-B1-S11-B1
Power: 24DC
Protection: IP56”